Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Circulation ; 148(13): 989-999, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37624364

RESUMO

BACKGROUND: Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbreviated dual antiplatelet therapy duration after percutaneous coronary intervention (PCI). The aim of this study was to compare the safety and effectiveness of the biodegradable-polymer sirolimus-eluting stent with the durable-polymer zotarolimus-eluting stent in patients at high bleeding risk receiving 1 month of dual antiplatelet therapy after PCI. METHODS: The Bioflow-DAPT Study is an international, randomized, open-label trial conducted at 52 interventional cardiology hospitals in 18 countries from February 24, 2020, through September 20, 2021. Patients with a clinical indication to PCI because of acute or chronic coronary syndrome who fulfilled 1 or more criteria for high bleeding risk were eligible for enrollment. Patients were randomized to receive either biodegradable-polymer sirolimus-eluting stents or durable-polymer, slow-release zotarolimus-eluting stents after successful lesion preparation, followed by 1 month of dual antiplatelet therapy and thereafter single antiplatelet therapy. The primary outcome was the composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year, and was powered for noninferiority, with an absolute margin of 4.1% at 1-sided 5% alpha. RESULTS: A total of 1948 patients at high bleeding risk were randomly assigned (1:1) to receive biodegradable-polymer sirolimus-eluting stents (969 patients) or durable-polymer zotarolimus-eluting stents (979 patients). At 1 year, the primary outcome was observed in 33 of 969 patients (3.6%) in the biodegradable-polymer sirolimus-eluting stent group and in 32 of 979 patients (3.4%) in the durable-polymer zotarolimus-eluting stent group (risk difference, 0.2 percentage points; upper boundary of the 1-sided 95% CI, 1.8; upper boundary of the 1-sided 97.5% CI, 2.1; P<0.0001 for noninferiority for both tests). CONCLUSIONS: Among patients at high risk for bleeding who received 1 month of dual antiplatelet therapy after PCI, the use of biodegradable-polymer sirolimus-eluting stents was noninferior to the use of durable-polymer zotarolimus-eluting stents with regard to the composite of death from cardiac causes, myocardial infarction, or stent thrombosis. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04137510.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento , Implantes Absorvíveis , Sirolimo/efeitos adversos , Infarto do Miocárdio/tratamento farmacológico , Stents/efeitos adversos , Trombose/etiologia
2.
Cardiovasc Revasc Med ; 56: 75-81, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37328392

RESUMO

BACKGROUND: Drug-coated balloon (DCB) angioplasty with paclitaxel-eluting devices is an established treatment for coronary in-stent restenosis (ISR). Biolimus A9™ (BA9), a sirolimus analogue with enhanced lipophilicity, may facilitate enhanced local drug delivery into vascular tissue. A novel DCB coated with Biolimus A9™ represents an alternative to traditional paclitaxel- and sirolimus-coated devices. Hence, we sought to investigate the safety and efficacy of this novel DCB in the treatment of coronary ISR. METHODS AND DESIGN: REFORM (NCT04079192) is a prospective, multicenter, single blind, randomized controlled trial comparing the BA9-DCB (Biosensors Europe SA, Morges, Switzerland) to the paclitaxel-coated SeQuent® Please DCB (Braun Melsungen AG, Germany) in the treatment of coronary ISR. A total of 201 patients with coronary artery disease and an indication for interventional treatment of ISR in a bare-metal stent (BMS) or drug-eluting stent (DES) have been randomized 2:1 to receive treatment with the BA9- or the paclitaxel-DCB comparator. Patients were enrolled across 24 investigational centers in Europe and Asia. The primary endpoint is percent diameter stenosis (%DS) of the target segment as assessed by quantitative coronary angiography (QCA) at 6 months. Key secondary endpoints are in-stent late lumen loss, binary restenosis, target lesion failure, target vessel failure, myocardial infarction and death at 6 months. Subjects will be followed for 24 months from enrolment. IMPLICATIONS: The REFORM trial will seek to prove that the BA9-DCB is non-inferior to the standard paclitaxel-DCB comparator in the treatment of coronary ISR with respect to %DS at 6 months and has similar safety characteristics.


Assuntos
Fármacos Cardiovasculares , Reestenose Coronária , Stents Farmacológicos , Humanos , Preparações Farmacêuticas , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Constrição Patológica , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Sirolimo/efeitos adversos , Paclitaxel/efeitos adversos , Materiais Revestidos Biocompatíveis
3.
J Cardiovasc Transl Res ; 16(5): 1135-1143, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37264295

RESUMO

The optimal duration of dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients undergoing percutaneous coronary intervention (PCI) with implantation of the Orsiro Mission stent remains unclear. The BIOFLOW-DAPT (clinicaltrials.gov, NCT04137510) trial is a prospective, multi-center, randomized controlled study designed to assess the safety of the Orsiro Mission versus the Resolute Onyx stent in HBR patients. Patients are treated with DAPT (aspirin and a P2Y12 inhibitor) for 1 month, followed by a single antiplatelet therapy (SAPT). The primary endpoint is the composite of cardiac death, myocardial infarction, and definite or probable stent thrombosis at 1 year. With a final sample size of 1948 HBR patients, this study is powered to assess the noninferiority of the Orsiro Mission stent with respect to the primary study endpoint. The BIOFLOW-DAPT is the first randomized clinical trial investigating 1-month DAPT duration in HBR patients after implantation of the Orsiro Mission stent.Trial Registration: ClinicalTrials.gov number, NCT04137510 Study design and key features. Patient selection starts before the index PCI, when consented patients will be randomized to the Orsiro Mission or the Resolute Onyx stent with mandated 1-month DAPT. At 1 month, eligibility is reassessed and if met, patients will discontinue DAPT and continue with P2Y12 inhibitor or aspirin monotherapy. PCI, percutaneous coronary intervention; DAPT, dual antiplatelet therapy; DES, drug-eluting stent; HBR, high bleeding risk; P2Y12i, P2Y12 inhibitor; ST, stent thrombosis.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Humanos , Inibidores da Agregação Plaquetária , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Aspirina/uso terapêutico , Stents , Trombose/prevenção & controle , Trombose/induzido quimicamente , Resultado do Tratamento
4.
Cardiovasc Revasc Med ; 52: 30-36, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36822974

RESUMO

BACKGROUND: Early-generation "sandwich-design" polytetrafluorethylene (PTFE) covered coronary stents (CS) are associated with a high frequency of adverse events. New-generation single layer PTFE-CS offers the potential to enhanced procedural efficacy and improves clinical safety. Data from a dedicated study, concerning outcomes after treatment with single-layer PTFE-CS in patients undergoing percutaneous coronary intervention are scant. METHODS: This is a retrospective multicenter registry including 30 patients undergoing implantation of 39 single-layer PTFE-CS (BeGraft-coronary Stent Graft System, Bentley InnoMed GmbH, Hechingen, Germany) in native coronary arteries or saphenous bypass grafts, in 3 centers in Europe, between May 2013 and May 2019. Endpoints of interest were procedural success (placement of covered stent), binary-angiographic restenosis (BAR), percent diameter stenosis (% DS) and late-lumen loss at 6-8 months follow-up angiography, rates of target lesion revascularization (TLR), myocardial infarction (MI), stent thrombosis (ST) and mortality at 12 months. RESULTS: 28 patients underwent implantation of 37 CS due to coronary artery perforation 2 patients due to coronary artery aneurysm. Technical success was achieved in all patients (100 %). More than one stent was implanted in 7 patients (25 %) all in the perforation group. Follow-up angiography was available in 23 patients (77 %) showing favorable results: BAR = 21.8 %, %DS = 30.3 ± 27.5; LLL = 0.16 ± 0.81 mm. At 12 months all patients were alive, rates of TLR were low (3 patients, 10.0 %), there was one case of late stent thrombosis (3.3 %) and one MI (3.3 %). CONCLUSIONS: In this dedicated study, implantation of a new single layer PTFE-CS for the treatment of native coronary arteries or saphenous vein grafts after perforation or due to aneurysm showed high technical success rates and favorable angiographic and clinical efficacy. Clinical safety outcomes are encouraging, but larger prospective studies are needed to determine long-term safety of this device.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Infarto do Miocárdio , Trombose , Humanos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents/efeitos adversos , Infarto do Miocárdio/etiologia , Resultado do Tratamento , Trombose/etiologia , Politetrafluoretileno , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Desenho de Prótese
5.
J Med Case Rep ; 16(1): 41, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35105350

RESUMO

BACKGROUND: Carcinoid heart disease is the cardiac manifestation of carcinoid syndrome. There is limited research on rhythm management in patients with carcinoid heart disease. The association of typical atrial flutter and carcinoid heart disease in particular is poorly described. CASE PRESENTATION: Here we present a case of a 77-year-old German woman with carcinoid heart disease and recurrent typical atrial flutter complicating the postoperative course after tricuspid valve replacement and its successful long-term rhythm control by ablation therapy. CONCLUSION: There is limited evidence on rhythm management in patients with the rare diagnosis of carcinoid heart disease. Typical atrial flutter repeatedly complicated the postoperative course of our patient with carcinoid heart disease and could finally be treated curatively by ablation. Radiofrequency ablation should be considered as a valuable therapeutic component in the challenging therapy of this disease.


Assuntos
Flutter Atrial , Doença Cardíaca Carcinoide , Ablação por Cateter , Ablação por Radiofrequência , Idoso , Flutter Atrial/cirurgia , Doença Cardíaca Carcinoide/complicações , Doença Cardíaca Carcinoide/diagnóstico por imagem , Doença Cardíaca Carcinoide/cirurgia , Feminino , Humanos , Recidiva Local de Neoplasia
7.
Cardiovasc. revasc. med ; 29: 9-15, Aug. 2021. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1293172

RESUMO

BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)- based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of −1.857 ± 1.902 mm2 at 1 year compared to −1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and − 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss. SUMMARY FOR TABLE OF CONTENTS: The authors analyzed 22 patients from the BIOSOLVE-II trial who underwent optical coherence tomography assessment immediately after receiving a Magmaris second-generation drug-eluting resorbable magnesium scaffold. The analysis found that after Magmaris implantation, the presence of higher endothelial shear stress (ESS) might be associated with slower strut absorption process but less luminal loss. This study is the first demonstrating the impact of ESS assessed by OCT on absorption process and coronary lumen dimension after Magmaris implantation.


Assuntos
Implantes Absorvíveis , Tomografia de Coerência Óptica , Magnésio , Resistência ao Cisalhamento , Stents Farmacológicos
8.
Cardiovasc Revasc Med ; 29: 9-15, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33863661

RESUMO

BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts' absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)-based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (<1.0 Pa), intermediate (1.0-2.5 Pa), or high (>2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of -1.857 ± 1.902 mm2 at 1 year compared to -1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and - 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Preparações Farmacêuticas , Implantes Absorvíveis , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Magnésio , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Tomografia de Coerência Óptica , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 96(5): 1008-1015, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31789486

RESUMO

BACKGROUND: Whether there exist differences concerning clinical outcomes between patients presenting with early versus late DES-ISR undergoing treatment with drug-coated balloons (DCB) remains a scientific knowledge gap. METHODS: This is a pooled analysis including patients with DES-ISR assigned to treatment with DCB in the setting of the ISAR DESIRE 3 and 4 trials. Clinical outcomes were evaluated according to time of occurrence of ISR after DES implantation, in patients presenting with early (≤12 months) versus late DES-ISR (>12 months) undergoing treatment with DCB. The primary endpoint of this analysis was major adverse cardiac event (MACE), defined as the combined incidence of death, myocardial infarction and target lesion revascularization (TLR) at 12 months after DCB treatment. Secondary endpoints included the incidence of death, myocardial infarction, TLR and target lesion thrombosis at 12 months after DCB treatment. RESULTS: This analysis included 352 patients, 199 patients presented with early-ISR, 153 patients with late-ISR. Concerning the primary endpoint, patients with early-DES-ISR as compared those with late-DES-ISR showed significant higher risk (25.9% vs. 17.0%; p = .04). In a multivariate analysis including diabetic status, clinical presentation, previous coronary bypass graft and diameter stenosis after DCB-treatment, the adjusted hazard ratio showed significant higher risk for MACE of early-DES-ISR as compared to late-DES-ISR (HRadj = 1.8, [95% CI = 1.1-3.0], p = .02). CONCLUSION: Clinical outcome at 12 months after treatment of DES-ISR with DCB, showed significant higher clinical event rates in patients presenting with early DES restenosis, as compared with patients presenting with late DES restenosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
N Engl J Med ; 381(16): 1524-1534, 2019 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-31475799

RESUMO

BACKGROUND: The relative merits of ticagrelor as compared with prasugrel in patients with acute coronary syndromes for whom invasive evaluation is planned are uncertain. METHODS: In this multicenter, randomized, open-label trial, we randomly assigned patients who presented with acute coronary syndromes and for whom invasive evaluation was planned to receive either ticagrelor or prasugrel. The primary end point was the composite of death, myocardial infarction, or stroke at 1 year. A major secondary end point (the safety end point) was bleeding. RESULTS: A total of 4018 patients underwent randomization. A primary end-point event occurred in 184 of 2012 patients (9.3%) in the ticagrelor group and in 137 of 2006 patients (6.9%) in the prasugrel group (hazard ratio, 1.36; 95% confidence interval [CI], 1.09 to 1.70; P = 0.006). The respective incidences of the individual components of the primary end point in the ticagrelor group and the prasugrel group were as follows: death, 4.5% and 3.7%; myocardial infarction, 4.8% and 3.0%; and stroke, 1.1% and 1.0%. Definite or probable stent thrombosis occurred in 1.3% of patients assigned to ticagrelor and 1.0% of patients assigned to prasugrel, and definite stent thrombosis occurred in 1.1% and 0.6%, respectively. Major bleeding (as defined by the Bleeding Academic Research Consortium scale) was observed in 5.4% of patients in the ticagrelor group and in 4.8% of patients in the prasugrel group (hazard ratio, 1.12; 95% CI, 0.83 to 1.51; P = 0.46). CONCLUSIONS: Among patients who presented with acute coronary syndromes with or without ST-segment elevation, the incidence of death, myocardial infarction, or stroke was significantly lower among those who received prasugrel than among those who received ticagrelor, and the incidence of major bleeding was not significantly different between the two groups. (Funded by the German Center for Cardiovascular Research and Deutsches Herzzentrum München; ISAR-REACT 5 ClinicalTrials.gov number, NCT01944800.).


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Inibidores da Agregação Plaquetária/uso terapêutico , Cloridrato de Prasugrel/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Ticagrelor/uso terapêutico , Síndrome Coronariana Aguda/mortalidade , Síndrome Coronariana Aguda/terapia , Idoso , Trombose Coronária/epidemiologia , Feminino , Hemorragia/induzido quimicamente , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/efeitos adversos , Cloridrato de Prasugrel/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Stents , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Ticagrelor/efeitos adversos
11.
Eur Heart J Cardiovasc Imaging ; 20(8): 916-924, Ago. 2019. tabela, gráfico, ilustração
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024905

RESUMO

AIMS : Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is an alternative novel device for treating coronary lesions. However, the relationship between in-scaffold dimensions after implantation of DREAMS 2G and vessel healing and luminal results at follow-up is unknown. The aim of this study is, therefore, to investigate whether the expansion index after implantation of DREAMS 2G as assessed by optical coherence tomography (OCT) impacts late luminal status and healing of the vessel wall. METHODS AND RESULTS : This study comprises of a total 65 out of 123 patients who were enrolled in the BIOSOLVE-II trial. We assessed both qualitative and quantitative OCT findings and the expansion index of DREAMS 2G after implantation frame by frame using OCT. Expansion index was defined as minimum scaffold area/mean reference lumen area. The over-expansion group was also defined with expansion index >1.0. The total number of analyzed frames at post-procedure and 6-month follow-up was 8243 and 8263 frames, respectively. At 6-month follow-up, in-scaffold healing was documented by the reduction of 82% in dissections, 93% in attached intra-luminal mass (ILM), 65% in non-attached ILM, and 76% in jailed side branch. The over-expansion group had significantly greater in-scaffold luminal volume loss (LVL) compared with the non-over-expansion group [over-expansion: 35.0 (18.5-52.1) mm3 vs. non-over-expansion: 21.0 (11.6-37.9) mm3, P = 0.039]. CONCLUSION : Excellent in vivo healing process after implantation of DREAMS 2G was observed at 6 months. We found that higher expansion indices were associated with higher in-scaffold LVL at 6 months assessed by OCT. (AU)


Assuntos
Vasos Coronários , Tomografia de Coerência Óptica , Stents Farmacológicos
12.
Am. j. cardiol ; 123(7): 1044-1051, Apr. 2019. tab, ilus, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1022205

RESUMO

Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is used for treating coronary lesions. However, the natural history of the jailed side-branch (SB) after DREAMS 2G implantation remains to be elucidated. The aim of this study is to investigate the effect of scaffold struts on jailed SBs as assessed by 3-dimensional (3D) optical coherence tomography (OCT) after implantation of DREAMS 2G. We enrolled the patients who received a DREAMS 2G implantation and where OCT was performed at postprocedure and 12-month follow-up in the BIOSOLVE-II trial. The area of the ostium of jailed SBs and number of compartments divided by scaffold struts were assessed by cut-plane analysis using 3D OCT. A total of 24 patients with 61 jailed SBs were analyzed in this study. The number of compartments was significantly decreased (postprocedure; 1.98 +/- 0.84 vs 12 months; 1.10 +/- 0.30, p <0.001) during the 12 months. Since most of the struts disappeared, the ostium area was increased in 62% of jailed SBs at 12 months, however, not significantly different from postprocedure (postprocedure; 0.74 [0.34 to 1.46] mm(2) vs 12 months; 0.78 [0.41 to 1.68] mm(2), p=0.055). The number of compartments created by scaffold struts and branching angle at postprocedure had no effect on the changes of SB ostium área. DREAMS 2G has a favorable absorption process in the jailed SBs up to 12 months and may be considered as an optional therapy for treating lesions that involve SBs. (AU)


Assuntos
Humanos , Doença da Artéria Coronariana , Tomografia de Coerência Óptica , Stents Farmacológicos
13.
Am J Cardiol ; 123(7): 1044-1051, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30683424

RESUMO

Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is used for treating coronary lesions. However, the natural history of the jailed side-branch (SB) after DREAMS 2G implantation remains to be elucidated. The aim of this study is to investigate the effect of scaffold struts on jailed SBs as assessed by 3-dimensional (3D) optical coherence tomography (OCT) after implantation of DREAMS 2G. We enrolled the patients who received a DREAMS 2G implantation and where OCT was performed at postprocedure and 12-month follow-up in the BIOSOLVE-II trial. The area of the ostium of jailed SBs and number of compartments divided by scaffold struts were assessed by cut-plane analysis using 3D OCT. A total of 24 patients with 61 jailed SBs were analyzed in this study. The number of compartments was significantly decreased (postprocedure; 1.98 ± 0.84 vs 12 months; 1.10 ± 0.30, p <0.001) during the 12 months. Since most of the struts disappeared, the ostium area was increased in 62% of jailed SBs at 12 months, however, not significantly different from postprocedure (postprocedure; 0.74 [0.34 to 1.46] mm2 vs 12 months; 0.78 [0.41 to 1.68] mm2, p = 0.055). The number of compartments created by scaffold struts and branching angle at postprocedure had no effect on the changes of SB ostium area. DREAMS 2G has a favorable absorption process in the jailed SBs up to 12 months and may be considered as an optional therapy for treating lesions that involve SBs.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Imageamento Tridimensional/métodos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Tecidos Suporte , Resultado do Tratamento
14.
Eur Heart J Cardiovasc Imaging ; 20(8): 916-924, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590578

RESUMO

AIMS: Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is an alternative novel device for treating coronary lesions. However, the relationship between in-scaffold dimensions after implantation of DREAMS 2G and vessel healing and luminal results at follow-up is unknown. The aim of this study is, therefore, to investigate whether the expansion index after implantation of DREAMS 2G as assessed by optical coherence tomography (OCT) impacts late luminal status and healing of the vessel wall. METHODS AND RESULTS: This study comprises of a total 65 out of 123 patients who were enrolled in the BIOSOLVE-II trial. We assessed both qualitative and quantitative OCT findings and the expansion index of DREAMS 2G after implantation frame by frame using OCT. Expansion index was defined as minimum scaffold area/mean reference lumen area. The over-expansion group was also defined with expansion index >1.0. The total number of analysed frames at post-procedure and 6-month follow-up was 8243 and 8263 frames, respectively. At 6-month follow-up, in-scaffold healing was documented by the reduction of 82% in dissections, 93% in attached intra-luminal mass (ILM), 65% in non-attached ILM, and 76% in jailed side branch. The over-expansion group had significantly greater in-scaffold luminal volume loss (LVL) compared with the non-over-expansion group [over-expansion: 35.0 (18.5-52.1) mm3 vs. non-over-expansion: 21.0 (11.6-37.9) mm3, P = 0.039]. CONCLUSION: Excellent in vivo healing process after implantation of DREAMS 2G was observed at 6 months. We found that higher expansion indices were associated with higher in-scaffold LVL at 6 months assessed by OCT.


Assuntos
Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Tomografia de Coerência Óptica , Cicatrização , Implantes Absorvíveis , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/administração & dosagem
15.
Catheter. cardiovasc. interv ; 92(7): 502, : 511, Dec. 2018. graf, tab, ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247595

RESUMO

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 6 10.8 years and mean lesion reference diameter was 2.70 6 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P 5 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 6 0.31 mm in-segment and 0.396 0.34 mm in scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Intervenção Coronária Percutânea , Implantes Absorvíveis , Stents Farmacológicos
16.
Catheter Cardiovasc Interv ; 92(7): E502-E511, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30079472

RESUMO

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug-eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 ± 10.8 years and mean lesion reference diameter was 2.70 ± 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P = 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 ± 0.31 mm in-segment and 0.39 ± 0.34 mm in-scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários , Stents Farmacológicos , Metais , Intervenção Coronária Percutânea/instrumentação , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
EuroIntervention ; 14(10): 1096-1103, 2018 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-29808819

RESUMO

AIMS: Although several studies have shown positive outcomes after the use of drug-coated balloons (DCB) for in-stent restenosis (ISR), data on randomised controlled trials versus latest-generation drug-eluting stents (DES) are limited. Therefore, in this randomised trial, we sought to evaluate whether a butyryl-tri-hexyl citrate (BTHC)-based paclitaxel DCB is non-inferior to a biodegradable polymer sirolimus-eluting stent (BP-SES) therapy in patients with ISR in either a bare metal stent (BMS) or DES. METHODS AND RESULTS: A total of 229 patients with ISR in BMS or DES from 13 German centres and one Latvian centre were 2:1 randomly allocated to DCB (n=157) or DES (n=72). The primary efficacy endpoint was defined as in-stent late lumen loss (LLL) at six months, and the primary safety endpoint was target lesion failure (TLF) at 12 months. LLL in the DCB arm was 0.03±0.40 mm compared to 0.20±0.70 mm in the DES arm (p=0.40). DCB proved to be non-inferior to DES (Δ = -0.17±0.52 mm, 97.5% CI -∞; -0.01]; p<0.0001). At 12 months, Kaplan-Meier TLF estimates were 16.7% in the DCB arm and 14.2% in the DES arm (p=0.65) and remained similar at 18 months (DCB versus DES: 17.4% versus 19.5%, p=0.88). CONCLUSIONS: In patients with DES or BMS ISR, treatment with a paclitaxel DCB showed similar LLL at six months and TLF rates up to 18 months compared to a second-generation sirolimus DES.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Angiografia Coronária , Humanos , Paclitaxel , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
18.
Cardiol Ther ; 7(1): 79-87, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29633088

RESUMO

INTRODUCTION: For patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI), proper antithrombotic therapy is equivocal. Current guidelines recommend triple therapy, which carries a high risk of bleeding. Recent large trials suggest that dual therapy (DT) with novel oral anticoagulant (NOAC) plus P2Y12 inhibitor can be an appropriate alternative, but real-world data for this alternative are scarce and the optimal duration of DT has not yet been established. METHODS: This analysis was performed in a single-center prospective cohort. We investigated 216 PCI patients with indication for anticoagulation due to AF. After PCI patients received DT with reduced doses NOAC plus P2Y12 inhibitor for 6 months, which was followed by standard dose NOAC monotherapy. Efficacy endpoints were defined as cardiac death, myocardial infarction (MI), stent thrombosis (ST), and stroke. Safety endpoints were bleeding events as defined by Bleeding Academic Consortium (BARC). RESULTS: Baseline characteristics of our study population were described by a CHA2DS2-VASc score of greater than 4 and a HAS-BLED score of greater than 3. After a mean follow-up of 18.7 months, efficacy events occurred in 12 patients (5.6%). We observed three (1.4%) cardiac deaths, two (0.9%) MIs, six (2.8%) strokes, and one (0.5%) definite ST. After switching from DT to NOAC monotherapy after 6.3 ± 1.7 months, there was no rebound of ischemic events. Bleeding events occurred in 34 patients (15.7%) mainly under DT, while bleeding was less during NOAC monotherapy. CONCLUSIONS: In this long-term study of high-risk and real-world AF-patients with PCI, DT with NOAC and P2Y12 inhibitor (6 months) followed by NOAC monotherapy was safe and effective.

19.
Int J Cardiol ; 255: 22-28, 2018 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-29292064

RESUMO

RATIONALE: Bioresorbable scaffolds may confer clinical benefit in long-term studies; early mechanistic studies using intravascular imaging have provided insightful information about the immediate and mid-term local serial effects of BRS on the coronary vessel wall. OBJECTIVES: We assessed baseline, 6- and 12-month imaging data of the drug-eluting absorbable metal scaffold (DREAMS 2G). METHODS AND RESULTS: The international, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to 2 de novo lesions (in vessels of 2.2 to 3.7mm). Angiographic based vasomotion, curvature and angulation were assessed; intravascular ultrasound (IVUS) derived radiofrequency (RF) data analysis and echogenicity were evaluated; optical coherence tomography (OCT) attenuation and backscattering analysis were also performed. There was hardly any difference in curvature between pre-procedure and 12months (-0.0019; p=0.48). The change in angulation from pre- to 12months was negligible (-3.58°; 95% CI [-5.97, -1.20]), but statistically significant. At 6months, the change in QCA based minimum lumen diameter in response to high dose of acetylcholine and IVUS-RF necrotic core percentage showed an inverse relationship (estimate of -0.489; p=0.055) and with fibrous volume a positive relationship (estimate of 0.53, p=0.035). Bioresorption analysis by OCT showed that the maximum attenuation values decreased significantly from post-procedure at 6months (Δ 6months vs. post-proc. is -13.5 [95% CI -14.6, -12.4]) and at 12months (Δ 12months vs. post-proc. is -14.0 [95% CI -15.4, -12.6]). By radiofrequency data, the percentage of dense calcium decreased significantly from post-procedure at 6months and at 12months. Likewise, by echogenicity, hyperechogenic structures decreased significantly from post-procedure at 6months; thereafter, they remained unchanged. CONCLUSION: Following implantation of DREAMS 2G, restoration of the vessel geometry, vasomotion and bioresorption signs were observed at up to 12months; importantly, these changes occurred with preservation of the lumen size between 6 and 12months. NCT01960504.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Tecidos Suporte , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis/tendências , Idoso , Stents Farmacológicos/tendências , Feminino , Seguimentos , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos , Tecidos Suporte/tendências , Tomografia de Coerência Óptica/tendências
20.
Int J Cardiol ; 255(mar): 22-28, 2018. tab, graf, ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063465

RESUMO

RATIONALE: Bioresorbable scaffolds may confer clinical benefit in long-term studies; early mechanistic studies using intravascular imaging have provided insightful information about the immediate and mid-term local serial effects of BRS on the coronary vessel wall. OBJECTIVES: We assessed baseline, 6- and 12-month imaging data of the drug-eluting absorbable metal scaffold (DREAMS 2G). METHODS AND RESULTS: The international, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to 2 de novo lesions (in vessels of 2.2 to 3.7mm). Angiographic based vasomotion, curvature and angulation were assessed; intravascular ultrasound (IVUS) derived radiofrequency (RF) data analysis and echogenicity were evaluated; optical coherence tomography (OCT) attenuation and backscattering analysis were also performed. There was hardly any difference in curvature between pre-procedure and 12months (-0.0019; p=0.48). The change in angulation from pre- to 12months was negligible (-3.58°; 95% CI [-5.97, -1.20]), but statistically significant. At 6months, the change in QCA based minimum lumen diameter in response to high dose of acetylcholine and IVUS-RF necrotic core percentage showed an inverse relationship (estimate of -0.489; p=0.055) and with fibrous volume a positive relationship (estimate of 0.53, p=0.035). Bioresorption analysis by OCT showed that the maximum attenuation values decreased significantly from post-procedure at 6months (Δ 6months vs. post-proc. is -13.5 [95% CI -14.6, -12.4]) and at 12months (Δ 12months vs. post-proc. is -14.0 [95% CI -15.4, -12.6]). By radiofrequency data, the percentage of dense calcium decreased significantly from post-procedure at 6months and at 12months...


Assuntos
Doença da Artéria Coronariana , Sirolimo , Stents Farmacológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...